3Com 5500-EI PWR Install Manual page 997

Hide thumbs Also See for 5500-EI PWR:
Table of Contents

Advertisement

8)
Configuring UDP test on remote-ping client
Follow these steps to configure UDP test on remote-ping client:
To do...
Enter system view
Enable the
remote-ping client
function
Create a remote-ping
test group and enter
its view
Configure the
destination address
Configure the
destination port
Configure the source
IP address
Configure the source
port
Configure the test
type
Configure the number
of probes per test
Configure the
maximum number of
history records that
can be saved
Configure the data
packet size
Configure a stuffing
character string
Use the command...
system-view
remote-ping-agent enable
remote-ping
administrator-name
operation- tag
destination-ip ip-address
destination-port
port-number
source-ip ip-address
source-port port-number
test-type { udpprivate |
udppublic }
count times
history-records number
datasize size
datafill string
1-18
Remarks
Required
By default, the remote-ping client function
is disabled.
Required
By default, no test group is configured.
Required
This IP address and the one configured on
the remote-ping server for listening service
must be the same.
By default, no destination address is
configured.
Required in a Udpprivate test
A Udppublic test is a UDP connection
test
on
port
remote-ping-server udpecho ip-address
7 command on the server to configure
the listening service port; otherwise the
test will fail. No port number needs to be
configured on the client; any destination
port number configured on the client will
not take effect.
By default, no destination port number is
configured.
Optional
By default, no source IP address is
configured.
Optional
By default, no source port is specified.
Required
By default, the test type is ICMP.
Optional
By default, one probe is made per test.
Optional
By default, the maximum number is 50.
Optional
By default, the data packet size is 100
bytes.
Optional
By default, the numbers between 0 and 255
are stuffed into datagrams in a cyclically
way.
7.
Use
the

Advertisement

Table of Contents
loading

This manual is also suitable for: