Tape Alert
E-mail Message Error
Flag
Type
4
Soft Error
5
Hardware Failure
6
Hardware Failure
9
Hardware Failure
13
Hardware Failure
14
Hardware Failure
20
Soft Error
22
Soft Error
30
Hardware Failure
31
Hardware Failure
33
Soft Error
40
Hardware Failure
41
Soft Error
43
Operator Access
44
Hardware Failure
45
Hardware Failure
Tandberg Data M-Series Remote Management Card User's Guide
Description
Media can no longer be written or read, or performance is
severely degraded
The drive can no longer read data from the tape
The drive can no longer write data to the tape
Write command attempted to a write-protected tape
Tape snapped or cut in the drive where media can be
ejected
Tape snapped or cut in the drive where media cannot be
ejected
The drive has a head clog or needs cleaning
The cleaning tape has expired
The drive has a hardware fault that requires a reset to
recover
The drive has a hardware fault that requires a power cycle
to continue
Error recovery action
Library mechanism is having trouble communicating with
the tape drive
Stray tape left in library after previous error recovery
Library door open
The library mechanism had a hardware fault that is not
mechanically related
Library magazine not present