E-mail Message Error
FSC Code
Type
2005
Hardware Failure
2006
Hardware Failure
2009
Hardware Failure
2012
Hardware Failure
2013
Hardware Failure
2014
Hardware Failure
2015
Hardware Failure
2016
Hardware Failure
2017
Hardware Failure
201A
Soft Error
201B
Soft Error
201C
Soft Error
201D
Soft Error
201E
Soft Error
201F
Soft Error
2023
Hardware Failure
2024
Hardware Failure
2025
Hardware Failure
2026
Hardware Failure
2027
Hardware Failure
2028
Hardware Failure
2029
Hardware Failure
2100
Hardware Failure
2101
Hardware Failure
2102
Hardware Failure
2103
Hardware Failure
2105
Hardware Failure
2106
Hardware Failure
2107
Hardware Failure
Tandberg Data M-Series Remote Management Card User's Guide
Description
Drive timeout waiting for status (drive 5 in this frame)
Drive timeout waiting for status (drive 6 in this frame)
Requires newer version of system board
Invalid byte received from drive 1 in this frame
Invalid byte received from drive 2 in this frame
Invalid byte received from drive 3 in this frame
Invalid byte received from drive 4 in this frame
Invalid byte received from drive 5 in this frame
Invalid byte received from drive 6 in this frame
Invalid packet received from drive 1 in this frame
Invalid packet received from drive 2 in this frame
Invalid packet received from drive 3 in this frame
Invalid packet received from drive 4 in this frame
Invalid packet received from drive 5 in this frame
Invalid packet received from drive 6 in this frame
Could not get a semaphore from OS
Response packet received from drive 1 in this frame indicates
command failed
Response packet received from drive 2 in this frame indicates
command failed
Response packet received from drive 3 in this frame indicates
command failed
Response packet received from drive 4 in this frame indicates
command failed
Response packet received from drive 5 in this frame indicates
command failed
Response packet received from drive 6 in this frame indicates
command failed
I2C interface failed to initialize
Timed out waiting for I2C bus to go not busy
No acknowledge received from slave
Exceeded retry limit while trying to send message
Message received from I2C bus but destination is unknown
Message to send over I2C bus is too large (see path)
Message received over I2C bus is too large
65