Tandberg Data MSERIES RMC USER User Manual page 75

Remote management card
Table of Contents

Advertisement

E-mail Message Error
FSC Code
Type
2030
Hardware Failure
2031
Hardware Failure
2034
Hardware Failure
2035
Hardware Failure
2036
Hardware Failure
2037
Hardware Failure
2038
Hardware Failure
2039
Hardware Failure
2104
Hardware Failure
2303
Hardware Failure
2409
Hardware Failure
240A
Hardware Failure
240B
Soft Error
240C
Soft Error
240D
Soft Error
240E
Hardware Failure
240F
Hardware Failure
2410
Hardware Failure
2411
Hardware Failure
2412
Hardware Failure
2414
Soft Error
2417
Soft Error
2419
Soft Error
241A
Soft Error
241B
Soft Error
241C
Soft Error
241D
Soft Error
241E
Soft Error
2504
Soft Error
2612
Soft Error
Tandberg Data M-Series Remote Management Card User's Guide
Description
Response packet received from drive 5 in this frame indicates
command failed
Response packet received from drive 6 in this frame indicates
command failed
Response received from drive 1 in this frame indicates drive busy
Response received from drive 2 in this frame indicates drive busy
Response received from drive 3 in this frame indicates drive busy
Response received from drive 4 in this frame indicates drive busy
Response received from drive 5 in this frame indicates drive busy
Response received from drive 6 in this frame indicates drive busy
Expected response from hardware was not received
Barcode reader did not find a barcode
Magazine removed when door was shut
Magazine inserted without proper access
Demo stopped; no slot available for cartridge destination
Sequence stopped; no cartridge available to perform requested
action
Librarian uncertain of cartridge origin
Manual intervention required to remove cartridge from the elevator
The requested move cannot be performed
The requested move cannot be performed
Autoclean cannot be performed as there are no cleaning tapes
Autoclean cannot be performed as all the cleaning tapes are in use
Demo unable to select random start slot. Try rerunning demo.
Fixed slot reserved for dedicated cleaner; not for general use
Illegal magazine configuration. Recheck.
Stack contains modules configured for different media to stack-
master
Fixed slot detected when library configured for 6 drive operation
No fixed slot detected when library configured for 5 drive operation
Magazine 5 detected when library configured for 6 drive operation
Drive 3 in this frame detected when library configured for 5 drive
operation
Bad page code in send diagnostic
Requested action cannot be carried out with a cartridge in the hand