Power Supply Input Ok Led Is Red - Cisco 9134 - MDS Multilayer Fabric Switch Troubleshooting Manual

Mds 9000 family
Hide thumbs Also See for 9134 - MDS Multilayer Fabric Switch:
Table of Contents

Advertisement

Chapter 4
Troubleshooting Hardware
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
Table 4-1
All Power Supply LEDS Are Off
Symptom
Possible Cause
All power supply
Power supply is not correctly seated in
LEDS are off.
the chassis.
Power supply is shut down.
Power supply is not operational.

Power Supply Input Ok LED is Red

Symptom
Table 4-2
Power Supply INput Ok LED Is Red
Symptom
Possible Cause
Power supply Input
Power supply is not correctly seated in
Ok LED is red.
the chassis.
PEMs on a Cisco MDS 9500 Series
chassis are not correctly installed.
External power source is not operational. Power down the switch and verify the external power
Power supply is not operational.
OL-9285-05
Power supply Input Ok LED is red.
Solution
Remove and reinstall the power supply. Refer to the
appropriate hardware installation guide for your chassis.
Choose Physical > Power Supplies and check the
OperStatus on Device Manager, or use the show
environment power CLI command to determine if the
power supply is shut down. If the status is shutdown, then
the supervisor has shutdown the power supply. The supervisor
shuts down the lower capacity power supply only if it detects
a mismatched pair of power supplies and the mode is
redundant or if there is a transition from combined to
redundant mode. If both power supplies are the same capacity
or the mode is combined, Cisco SAN-OS never shuts down a
power supply.
Troubleshoot the power supplies. See the
the Power Supplies" section on page
Solution
Remove and reinstall the power supply. Refer to the
appropriate hardware installation guide for your chassis.
Remove and reinstall the power supply PEMs. Refer to the
appropriate hardware installation guide for your chassis.
source. Use independent power sources to each redundant
power supply in a Cisco MDS 9500 Series director.
Troubleshoot the power supplies. See the
the Power Supplies" section on page
Cisco MDS 9000 Family Troubleshooting Guide, Release 3.x
Troubleshooting Power Supply Issues
"Troubleshooting
4-7.
"Troubleshooting
4-7.