Common Problems with Port Interfaces
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
Symptom
Table 8-3
Port Remains in a Link-Failure State
Symptom
Possible Cause
Port remains in a
Port connection is bad.
link-failure state.
There is no signal because of a transit fault in the
SFP or the SFP may be faulty.
Link is stuck in initialization state or the link is in
a point-to-point state.
Note
We recommend that you do not disable and then enable a T or TE port. This would affect all the VSANs
crossing the EISL instead of just the VSAN experiencing the problem.
Cisco MDS 9000 Family Troubleshooting Guide, Release 3.x
8-14
Port remains in a link-failure state.
Chapter 8
Solution
Use the show port internal info CLI command to
verify the port status is in link-failure. Use the
show hardware internal fc-mac port port
gbic-info CLI command to determine if there is a
signal present.
You must use the attach module CLI
Note
command to access the FC-MAC show
commands.
Verify the type of media in use. Is it copper or
optical, single-mode (SM) or multimode (MM)?
Verify that the media is not broken or damaged. Is
the LED on the switch green? Is the active LED on
the host bus adapter (HBA) for the connected
device on?
Right-click on the port in Device Manager and
select disable and then enable, or use the shut
CLI command followed by the no shut command
to disable and enable the port. If this does not
clear the problem, try moving the connection to a
different port on the same or another module.
When this occurs, the port stays in a transit port
state and you see no signal. There is no
synchronization at the MAC level. The problem
may be related to the port speed setting or
autonegotiation. See the
"Troubleshooting Port
Problems" section on page
SFP on the interface is seated properly. If
reseating the SFP does not resolve the issue,
replace the SFP or try another port on the switch.
Choose Logs > Switch Resident > Syslog on
Device Manager or use the show logging CLI
command to check for a
Link Failure, Not
system message.
Connected
Right-click on the port in Device Manager and
select disable and then enable, or use the shut
CLI command followed by the no shut command
to disable and enable the port. If this does not
clear the problem, try moving the connection to a
different port on the same or another module.
Troubleshooting Ports
8-15. Verify that the
OL-9285-05

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents