Download Print this page

Walk Testing - Visonic CLIP PG2 Installation Instructions Manual

Powerg wireless, curtain, pir motion detector

Advertisement

2.4 Setting the Coverage Range

2.5 Walk Testing

A. Mount the cover and tighten the screw. Wait for the detector to stabilize (the LED stops flashing approx. 1 minute after the cover is closed).
B. Walk slowly across the far end of the curtain pattern (in opposite directions). The LED indicator lights for approx. 3 seconds whenever
you enter or exit a curtain beam.
Important: Perform walk test at least once a week to assure proper function of the detector.
Note: After closing the cover the detector enters a 15 minute walk-test mode. In this mode the LED will flash each time a detection
occurs, regardless of LED jumper settings, and the detector will transmit on the occurrence of each detection event.
2.6. Enrollment
Refer to the PowerMaster panel's Installer Guide and follow the procedure under the "02:ZONES/D
Menu. A general description of the procedure is provided in the following flow chart.
Step 1
Enter the Installer menu
and select
"02:ZONES/DEVICES"
02.ZONES/DEVICES
ADD NEW DEVICES
MODIFY DEVICES
means scroll
and select
Notes:
[1] If the detector is already enrolled you can configure the detector parameters via the "Modify Devices" option – see Step 2.
[2] Select the "Device Settings" option and refer to section 2.7 to configure the detector parameters.
2.7. Configuring the Detector Parameters
DEVICE SETTINGS
Enter the
Option
Define whether or not the alarm LED indication will be activated.
Alarm LED
Optional settings: LED ON (default) and LED OFF.
Select one of three ranges, according to the type of installation, for the curtain beams. Select "Maximum" for a
PIR RANGE
range of 6 m, select "
Optional settings: Maximum (default), Medium and Minimum.
Define whether or not to set the activity time during disarm
DISARM Activity
Optional settings: NOT Active (default),
delay, YES + 1m delay, YES + 2m delay, YES + 5m delay, YES + 10m delay, YES + 20m delay
YES + 60m delay
4
A
Step 2
Enroll the device or Enter
Select "ADD NEW
DEVICES" Option
See Note [1]
ENROLL NOW or
ENTR ID:XXX-XXXX
menu and follow the configuration instructions for the CLIP PG2 curtain detector as described in the following table.
" for a range of 4 m, or select
Medium
.
A. Window
Note: The CLIP PG2 can be mounted on either
side of a window.
Figure 14. Mounting on Both Sides of a Window
The CLIP PG2 can be programmed to select one of three ranges,
according to the type of installation, for the curtain beams (see
Figure 15 and section 2.7).
A. Minimum range
B. Medium range
C. Maximum range
Step 3
Step 4
Select the desired Zone
the device ID
Number
Z03:Motion Sens
ID No. 122-XXXX
Configuration Instructions
"Minimum"
.
,
YES – no delay
YES + 5s delay
D-303370 CLIP PG2 Installation Instructions
Figure 15. Range Setting Diagram
EVICES" option of the Installer
02:ZONES/DEVICES
02:ZONES/D
02:ZONES/D
EVICES
EVICES
Step 5
Configure Location,
Zone Type &
Chime Parameters
Z03.LOCATION
Z03.ZONE TYPE
Z03.SET CHIME
Z03.DEV SETTINGS
for a range of 2 m.
,
YES + 15s delay, YES + 30s
Step 6
Configure
the
Detector
See Note
[2]
and

Advertisement

loading