Precautions for Correct Use
Since the settings for Comment 2 and the subsequent comments are not included in the safety
application data, they are not transferred to the Safety CPU Unit.
Additional Information
The settings for Comment 2 and the subsequent comments are downloaded when the safety
application data is transferred, such as during the execution of validation check or transfer by
synchronization.
l Uploading Settings for Comment 2 and the Subsequent Comments from
the Controller
Use the following procedure to upload the settings for Comment 2 and the subsequent comments.
• Establish an online connection with the controller. Go to the Tools Menu and select Variable
Comment (Safety Program) - Transfer from Controller.
Additional Information
The settings for Comment 2 and the subsequent comments are uploaded when the transfer of
safety application data is executed by synchronization.
l Clearing Settings for Comment 2 and the Subsequent Comments from the
Controller
Use the following procedure to clear the settings for Comment 2 and the subsequent comments.
• Execute the Clear All Memory operation for the controller.
• Establish an online connection with the controller. Go to the Tools Menu and select Variable
Comment (Safety Program) - Clear variable comments in Controller.
NX-series Safety Control Unit/Communication Control Unit User's Manual (Z395)
8 Programming
8
8-85
Need help?
Do you have a question about the sysmac NX Series and is the answer not in the manual?