Chapter 6— Two-Dimensional Bar Codes
Example 1 Input:
Example 1 Output:
Example 1 decodes to: 028860000[GS]057[GS]057[GS]This is a MAXICODE low priority
Example 2 Input:
54
Tags Used When UPS5 is Turned On
Tag
Definition
EOT
End of transmission character
GS
Field separator character [GS]
RS
Format type separator [RS]
For more information on creating labels for the UPS shipping system, see
the document Guide to Bar Coding with UPS OnLine: for Customers
Generating Bar Code Labels, Version 5 available from the United Parcel
Service.
! 0 200 200 600 1
JOURNAL
B MAXICODE 20 20
CC 12345
MSG This is a MAXICODE low priority message.
SC 12345
POST 02886
ENDMAXICODE
PRINT
message.
! 0 200 200 600 1
JOURNAL
B MAXICODE 20 20
CC 12345
MSG This is a MAXICODE low priority message.
SC 12345
POST 02886
ZIPPER 1
ENDMAXICODE
PRINT