Gap Sense and Bar Sense Commands

Purpose: You use these commands to instruct the printer as to which means of top-
Format:
Example: The following example configures the printer for gap sensing. In addition,
EasyCoder PL-Series Printer Programmer's Reference Manual
of-form detection should be employed. Printers default to Gap Sense
mode if no command is specified. Printers that are not equipped with a
gap sensor attempt a pseudo gap sense.
{command}
where:
{command}: Choose one of the following:
GAP-SENSE # (0-255)
BAR-SENSE # (0-255)
You follow Gap and Bar Sense commands by a number to adjust the
sensitivity. This adjustment is useful for gap sense stock from vendors
other than Intermec.
it specifies that the distance from top-of-form to the gap is zero.
Input (GAPSENSE.LBL):
! UTILITIES
GAP-SENSE
SET-TOF 0
PRINT