Units Commands; Setlp Command - Intermec EasyCoder PL3 Programmer's Reference Manual

Intermec easycoder pl3: reference guide
Hide thumbs Also See for EasyCoder PL3:
Table of Contents

Advertisement

Example Input:
Example Output:

Units Commands

Purpose: The Units commands specify a measurement system for all subsequent
Format:

SETLP Command

Purpose: Selecting the line printer font (the SETLP command) changes the font the
Format:
EasyCoder PL-Series Printer Programmer's Reference Manual
Although this text is all on the same line, ! U1 SETLP 5
0 24 (CR/LF)this font is new.
To change the default settings for the printer, you can place any of these
commands in an AUTOEXEC.BAT file. For help, see "Batch Files" in
Chapter 14.
command fields in a utility session. You can enter coordinates, widths, and
heights for all utility commands with precision to four decimal places. The
printer measurement system defaults to dots until a units command is
issued.
<!> <UTILITIES>
{command}
<PRINT>
where:
{command}: Choose from the following:
IN-INCHES
IN-CENTIMETERS
IN-MILLIMETERS
IN-DOTS
printer uses for Line Print mode. It also chooses the amount of space the
printer moves down when the printer receives a carriage return (hex value
0x0d).
! U1 SETLP {font name or number} {size} {unit height}
SETLP allows you to use either the resident fonts or pre-scaled fonts
downloaded to the flash memory. The Intermec PLUS design software can
create and upload a font for the printer from any available TrueType
font. Appendix D, "Font Information," contains a table of all resident font
heights and their proper unit height.
Chapter 9— Line Print Mode
Measurement in inches.
Measurement in centimeters.
Measurement in millimeters.
Measurement in dots. The default
unit of measurement is in dots.
85

Advertisement

Table of Contents
loading

This manual is also suitable for:

Easycoder pl4Easycoder pl-series

Table of Contents