Chapter 1— Programming Introduction
Label Coordinate System
6
2 Hold the Feed button down.
3 Turn the printer on.
4 Release the Feed button when the printer starts printing the reports.
5 At the end of second report, the printer prints "Press Feed button to
enter Dump mode."
6 Now press the Feed button. The printer prints "Entering Dump mode."
If you do not press the Feed button within 3 seconds, the printer prints
"Dump mode not entered" and resumes normal operation.
At this point, the printer is in Dump mode and prints the ASCII hex
codes of the data sent to it and their text representation (or "." if not a
printable character).
Additionally, a file with a ".DMP" extension containing the ASCII
information is created and stored in the printer's memory. You can view,
clone, or delete the file using the Intermec PLUS application. For help, see
the online help for the Intermec PLUS application.
To cancel Dump mode
1 Turn the printer off.
2 Wait 5 seconds.
3 Turn the printer on.
The x and y coordinates in the next illustration are in terms of dots. On
200 dpi printers, 8 dots (either horizontally or vertically) equal 1 mm and
203 dots approximately equal 1 inch.