Table 1-7
Cisco 12012 Electrical Specifications
Description
AC-input power
AC-input voltage
AC-input current rating
DC-input power
DC-input voltage
DC-input current rating
Table 1-8
Cisco 12012 Environmental Specifications
Description
Temperature
Humidity
Altitude
Heat dissipation
Acoustic Noise
Shock
1. g = gravity.
2. oct./min. = octave per minute.
Value
1560 watts
200–240 VAC nominal (single-phase)
9.5 amps (@ 200 VAC)
3000 watts
–48 VDC nominal in North America
–60 VDC nominal in the European Community
55 amps (A) @ 50 VDC
Value
32° to 104°F (0 to 40°C) operating
–4° to 149°F (–20 to 65°C) nonoperating
10 to 90% noncondensing operating
5 to 95% noncondensing nonoperating
0 to 10,000 ft (0 to 3,050 m) operating
0 to 30,000 ft (0 to 9,144 m) nonoperating
10,640 Btu/hr maximum
69 dbA maximum
1
5 to 500 Hz, 0.5g
(0.1 oct./min.
5 to 100 Hz, 1g (0.1 oct./min.) nonoperating
100 to 500 Hz, 1.5g (0.2 oct./min.)
500 to 1,000 Hz, 1.5g (0.2 oct./min.)
System Specifications
2
) operating
Product Overview 1-41