8-8. Clearing Method Selecting of the Sensor Disconnected Error
The clearing method of the sensor disconnected error can be selected.
When selecting the clearing method, set it by the dip switch (DSW2) located on the rear of the converter.
Clearing method of the
sensor disconnected
error
Auto clearing
(Factory setting)
Manual clearing
DSW2 setting
Automatically clears the error when removing the cause of
the sensor disconnected error.
ON 1 2 3 4
Keeps the sensor disconnected error until clearing the
error by manual.
ON 1 2 3 4
40
Description
Need help?
Do you have a question about the Absocoder NCV-40H Series and is the answer not in the manual?