Download Print this page

Performance Specification - NSD Absocoder NCV-40H Series Specifications & Instruction Manual

Advertisement

(2) Performance Specification

Items
Converter model
Applicable sensor
Total number of divisions
Output code
Position detection format
Number of
detection axes
Position data
sampling time
Status output signal
Input signal
Front panel function
Switch
(on rear face of product)
Monitor LED
NCV-40HB[ ]M5
Binary code output: 26-bit
Latch pulse (position data reading timing signal): 1 point
Position data increase direction setting (CW / CCW): 1 point
Position data update
cycle
HOLD signal format
LP signal logic (Non-inverted/Inverted): 1 point
Zero point setting function selection (Enabled/Disabled): 1 point
Clearing method setting of the sensor disconnected error
(auto clearing / manual clearing): 1-point
Output state monitor
Input state monitor
Error state monitor
Specifications
MRE-1024S16TS100
MRE-8192S2TS100
67108864 (2
26
Absolute position detection
1
0.1ms
System ready: 1 point
Error: 1 point
Position data HOLD signal: 1 point
Zero point setting signal: 1 point
Error clear signal: 1 point
Zero point setting, error clear
Edge timing
Level timing 1
Level timing 2
Transparent format
PC synchro format
Position data output, System ready output, Error output
HOLD input, zero point setting input, error clear input
Sensor disconnected error, Memory error,
Low power error, Sensor power supply error,
Switch setting error
5
NCV-40HG[ ]M5
)
Gray code output: 26-bit
0.1ms
0.2ms
0.4ms
0.8ms
0.8ms
1.6ms
3.2ms
6.4ms
3.2ms
6.4ms
12.8ms
25.6ms
51.2ms

Advertisement

loading
Need help?

Need help?

Do you have a question about the Absocoder NCV-40H Series and is the answer not in the manual?