11. Click Rename
12. Apply to save your changes.
13.3.3 Configure remote (leaf) data loggers
Follow steps 1 – 6 in
Configure the data logger acting as a
PakBus address to each leaf data logger. Do not configure leaf data loggers as routers.
13.3.3.1 Add leaf data loggers to the network
1. In the LoggerNet Standard Setup view (click the Setup
ensure you are in the Standard view), right-click on the router data logger in the Entire
Network pane on the left side of the window and select CR300Series.
2. With the newly added data logger selected in the Entire Network pane, set the PakBus
Address to the address that was assigned to the leaf data logger in Device Configuration
Utility.
3. Click Rename
4. Apply to save your changes.
5. Repeat these steps for each leaf data logger in the network.
to provide the data logger a descriptive name.
to provide the data logger a descriptive name.
router (p. 62) to assign a unique
option and click the View menu to
13. Radio communications option 67