Keepaliveurl (Ping Keep Alive Url); Keepalivemin (Ping Keep Alive Timeout Value); Maxpacketsize; Neighbors - Campbell CR300 Series Product Manual

Compact datalogger
Hide thumbs Also See for CR300 Series:
Table of Contents

Advertisement

If the value of this setting is false, the data logger will be configured to act as a leaf node. In this
configuration, the data logger will not be able to forward packets from one port to another and it
will not maintain a list of neighbors. Under this configuration, the data logger can still
communicate with other data loggers and wireless sensors. It cannot, however, be used as a
means of reaching those other data loggers. The default value is false.
 
Boolean data type
l

23.3.28 KeepAliveURL (Ping keep alive URL)

The URL to send a ping to when there has been no network activity for the KeepAliveMin interval.
If there is no ping response then the network connection is reestablished.
 
String data type
l

23.3.29 KeepAliveMin (Ping keep alive timeout value)

When there has been no network activity for this amount of time, in seconds, a ping will be sent
to the KeepAliveURL. Default = 0 which disables keep alive pings.
 
Long data type (allowed values: 0,5,10,15,30,60,120,180,240,300,360,480,720)
l

23.3.30 MaxPacketSize

Specifies the maximum number of bytes per data collection packet.

23.3.31 Neighbors

This setting specifies, for a given port, the explicit list of PakBus node addresses that the data
logger will accept as neighbors. If the list is empty (the default value) any node will be accepted
as a neighbor. This setting will not affect the acceptance of a neighbor if that neighbor's address
is greater than 3999.
 
String data type
l

23.3.32 PakBusAddress

This setting specifies the PakBus address for this device. Valid values are in the range 1 to 4094.
The value for this setting must be chosen such that the address of the device will be unique in the
23. Information tables and settings (advanced)     217