23.3.59.10 CellPwrRepeat

Specifies the interval in minutes to power on the cellular interface following the first time of the
day that the data logger powers on its cellular interface. For example usage, see CellPwrDuration.
 
Long data type
l
Where to find:
 
Settings Editor tab in Device Configuration Utility: Cellular > Repeat cycle
l

23.3.59.11 CellPwrStartTime

Specifies time of day in minutes when the data logger will first enable the cellular interface.
Examples:
 
15 = 00:15 '15 minutes after midnight
l
 
180 = 03:00 '3:00 am
l
 
1380 = 23:00 '11:00 pm
l
 
1440 = Always On
l
For example usage, see CellPwrDuration.
 
Long data type
l
Where to find:
 
Settings Editor tab in Device Configuration Utility: Cellular > Start (power-on) time
l

23.3.59.12 CellRSRQ

CellECIO
Specifies the signal quality of the modem. For 3G, this is ECIO (Energy to Interference Ratio). For
4G, this is RSRQ (Reference Signal Received Quality). Updated when queried by your data logger
support software or a program. Ranges expected for Signal Quality for 3G/4G:
Excellent: 0 to -6 (3G), >-9 (4G)
Good: -7 to -10 (3G), -9 to -12 (4G)
Fair to Poor: -11 to -20 (3G), -13 or less (4G)
 
Float data type
l
 
Read only
l
23. Information tables and settings (advanced)     226