5.6.4

Connect the AC input wires

Preliminary requirements
Procedure
1. Prepare the wires:
a. Cut the wires (A), (B) and (C). Make
b. Strip the insulation from the end
c. Attach the cable lugs to the end of
2. Attach the wires to the connectors:
Use the fasteners (F) on each connection.
3. Tighten the fasteners to the correct torque. For the specification, refer to
section 10.7.
5.6.5

Connect the Ethernet cable

Preliminary requirements
9AKK108466A3703-EN | 001
The front and right doors
are open.
Installation engineer
Wire stripper pliers, cable
lug tool and torque socket
wrench. Refer to section
10.5.
sure that the lenght is sufficient
for connection at the connectors
on the AC fuse (D).
of the wires. Make sure that the
strip length is compatible with the
cable lugs (E).
the wires. Use the cable lug tool.
L1 wire (A) to the connector (G)
L2 wire (B) to the connector (H)
L3 wire (C) to the connector (I)
The front and right doors
are open.
Cable lugs and fasteners.
Refer to section 10.6.
F
E
H
G
A
Installation engineer
Installation
D
I
C
B
51