17 17
16 16
12 12
6 6
19 19
4 4
15 15
5 5
Fig. 13:
Assembling the lever
The gap between the driver pin and the shaft should be the same as the actuator stroke. As a result,
the lever has a angular range of 60°. (see "Fig. 14").
Angular range of the position sensor:
The maximum angular range of the position sensor is 150°.
Rotational range of the lever:
To ensure that the position sensor operates at a good resolution, the rotational range of the lever
must be at least 30°.
The rotational movement of the lever must be within the position sensor rotation range of 150°.
The scale printed on the lever is not relevant.
Maximum rota-
tional range of the
Fig. 14:
Angular range of the lever
Attach lever to the shaft of the Type 8792/8793 and screw tight.
42
18 18
14 14
12 12
22 22
13 13
150°
lever
english
Type 8792, 8793
Type 8792, 8793
Attachment and assembly
Legend:
No.
Name
4
Driver pin
5
Conical roller
6
Lever
12
13
For a description of
14
the numbering,
15
refer to
16
"Table 11:
17
Attachment kit for
18
linear actuators"
19
22
Rotational range of the lever
Ideal: 60°
Minimal: 30°
Maximal: 150°
The rotational movement of the lever must
be within the position sensor angular range
of 150°.