Type 8792, 8793
Type 8792, 8793
Pneumatic connection
13
PNEUMATIC CONNECTION
13.1
Safety instructions
DANGER!
Risk of injury from high pressure in the equipment.
▶ Before loosening the pneumatic lines and valves, turn off the pressure and vent the pneumatic lines.
WARNING!
Risk of injury from improper installation.
▶ Installation may be carried out by authorized technicians only and with the appropriate tools.
Risk of injury from unintentional activation of the system and an uncontrolled restart.
▶ Secure system from unintentional activation.
▶ Following installation, ensure a controlled restart.
Fig. 22:
Fluid installation / Location of the connections
Working connection 2
(connection: A2)
Supply pressure connection 1.4 – 7 bar
(connection: P)
Working connection 1 <
(connection: A1)
Deaeration connection
english
51