Pneumatic Connection; Safety Instructions - Burkert 8792 Operating Instructions Manual

Electropneumatic positioner and process controller
Table of Contents

Advertisement

Type 8792, 8793
Type 8792, 8793

Pneumatic connection

13
PNEUMATIC CONNECTION
13.1

Safety instructions

DANGER!
Risk of injury from high pressure in the equipment.
▶ Before loosening the pneumatic lines and valves, turn off the pressure and vent the pneumatic lines.
WARNING!
Risk of injury from improper installation.
▶ Installation may be carried out by authorized technicians only and with the appropriate tools.
Risk of injury from unintentional activation of the system and an uncontrolled restart.
▶ Secure system from unintentional activation.
▶ Following installation, ensure a controlled restart.
Fig. 22:
Fluid installation / Location of the connections
Working connection 2
(connection: A2)
Supply pressure connection 1.4 – 7 bar
(connection: P)
Working connection 1 <
(connection: A1)
Deaeration connection
english
51