Chapter 4: Installers Guide; Register; Erase - Tele Radio TG-T12-20 Installation Instructions Manual

Industrial radio remote controls
Table of Contents

Advertisement

CHAPTER 4: INSTALLERS GUIDE

 

REGISTER

 
WARNING! Do not perform this when the receiver is in a session with another transmitter. The radio
communication may become disturbed or broken.
 
NOTE! Before starting to perform these settings, make sure that the stop relays are deactivated!
 
 
Register the transmitter in the receiver
 
1. Press the receiver Function button.
Function LED 1 flashes red.
 
2. Relay LEDs 1-7 light to show how many transmitters that are already registered in the receiver.
 
3. Press the receiver Select button until all relay LEDs light red.
The receiver will stay in registering mode for 1 minute or until a transmitter has been registered.
 
4. On the transmitter: Make sure that the stop button is pressed.
 
5. Pull out the stop button.
 
6. Press side button 3. Keep pressed.
 
7. Press the stop button.
 
8. Release side button 3.
 
9. Go to [Register].
 
10. Select an empty slot and confirm by pressing side button 4. The display shows [Registering].
 
11. When the receiver has found the transmitter, all relay LEDs flash red. The display shows [Confirm
on RX].
 
12. Press the receiver Select button. Function LEDs 1-7 flash 3 times. The relay LEDs go off.
 
13. All Function LEDs light for approx. 1 second. The transmitter is now registered in the receiver. The
transmitter turns off.
 
14. If registering fails, the display shows [FAILED]. The transmitter turns off.
 
 
 

ERASE

 
NOTE! If a transmitter is lost or becomes seriously damaged, it is possible to erase it from the receiver.
We do not recommend this way. Contact your representative for assistance.
 
1. Make sure that the stop button is pressed.
 
2. Pull out the stop button.
Chapter 4: INSTALLERS GUIDE