CHAPTER 4: INSTALLERS GUIDE

 

FUNCTIONALITY

 
The analogue output module D8-2/D8-4 has four channels, CH1-CH4. The four channels can output
one signal each. The output signals can be mapped to analogue levers, potentiometer, push button etc.
The analogue output modules are connected to the receiver with the RS485/MODBUS.
 
IMPORTANT! The Tiger system supports a maximum of four D8-2/D8-4 units. If all four modules are
connected to the receiver, unit one and two will have full functionality while units three and four will
only have limited functionality. This means that the output signal for units three and four can only be 0-
10V and that no scaling, ramping or offset of the output signal is possible. Contact your representative
for more information.
 
 
 
Signals in
RS485/MODBUS
D8-2/
D8-4
Signals out Signals out Signals out Signals out
- 8 -
Chapter 4: INSTALLERS GUIDE
RECEIVER
D8-2/
D8-2/
D8-2/
D8-4
D8-4
D8-4