The page includes the following fields:
Instance Data:
Object
 APS #
 Mode
 SMAC
 Level
 VLAN
 PCP
 Rev
 TxAps
 WTR
 HoldOff
 Enable
Buttons
: Click to apply changes
: Click to undo any changes made locally and revert to previously saved values.
: Return to the previous page; any changes made locally will be undone.
Description
The ID of the APS. Maximum number of creatable APS instances is 10 . Click on
link to get to APS instance page, you can reset counters and issue commands.
1:1 This will create a 1:1 APS
1+1 Uni This will create a 1+1 Unidirectional APS.
1+1 Bi This will create a 1+1 Bidirectional APS.
Source MAC address used in L-APS PDUs. Must be a unicast address. If all-
zeros, the switch port's MAC address will be used.
MD/MEG Level (0-7).
The VLAN ID used in the L-APS PDUs. 0 means untagged.
PCP (priority) (default 7). The PCP value used in the VLAN tag unless the L-
APS PDU is untagged. Must be a value in range 0 - 7.
When checked, the port recovery mode is revertive, that is, traffic switches back
to the working port after the condition(s) causing a switch has cleared. In the
case of clearing a command (e.g. forced switch), this happens immediately. In
the case of clearing of a defect, this generally happens after the expiry of the
WTR (Wait-To-Restore) timer.
When unchecked, the port recovery mode is non-revertive and traffic is allowed
to remain on the protect port after a switch reason has cleared.
Choose whether this end transmits APS PDUs. Only used for 1+1,
unidirectional.
When Rev is checked, WTR (Wait-To-Restore) tells how many seconds to wait
before restoring to the working port after a fault condition has cleared. Valid
range 1 - 720
When a new (or more severe) defect occurs, the hold-off timer will be started
and the event will be reported after the timer expires. HoldOff time is measured
in milliseconds, and valid values are in the range 0 - 10000. Default is 0, which
means immediate reporting of the defect.
The administrative state of this APS instance. Check to make it function normally
and uncheck to make it cease functioning.