Advanced Settings
Object
Edge Port BPDU
Filtering
Edge Port BPDU
Guard
 Port Error Recovery
Port Error Recovery
Timeout
The Industrial Managed Switch implements the Rapid Spanning Protocol as the default spanning
tree protocol. When selecting "Compatibles" mode, the system uses the RSTP (802.1w) to be
compatible and to co-work with another STP (802.1D)'s BPDU control packet.
Buttons
: Click to apply changes
: Click to undo any changes made locally and revert to previously saved values.
Description
Control whether a port explicitly configured as Edge will transmit and receive
BPDUs.
Control whether a port explicitly configured as Edge will disable itself upon
reception of a BPDU. The port will enter the error-disabled state, and will be
removed from the active topology.
Control whether a port in the error-disabled state automatically will be enabled
after a certain time. If recovery is not enabled, ports have to be disabled and re-
enabled for normal STP operation. The condition is also cleared by a system
reboot.
The time that has to pass before a port in the error-disabled state can be
enabled. Valid values are between 30 and 86400 seconds (24 hours).