Brake control

Influence of the brake control on the state machine

The following state changes are decelerated, if delay on is activated in co21 bit 5
sc:
State change
start operation active
operation enabled
shutdown operation active
ready to switch on
disable operation active
switched on
fault reaction active
fault
i

Times of the brake control

The times of the brake control can be influenced by the following objects:
Index
Id-Text Name
0x2516
co22
brake ctrl open delay
0x2517
co23
brake ctrl open time
0x2518
co24
brake ctrl closing delay
0x2519
co25
brake ctrl closing time

Status of the brake control

The status of the brake control can be displayed via the following object:
Index
Id-Text Name
0x2104
st04
brake ctrl status
© 2022 KEB Automation KG
Description
The modulation is enabled in state "start operation active" and speed = 0
is preset. Subsequently, the setpoint of the brake control (CMD) is set to
1.
After the assumed state of the brake (Val) has reached value 1 (open
brake), the state machine changes to "Operation enabled".
Speed shutdown to 0 in state "shutdown operation active" depending on
the selected ramp (standard ramp) or
reaction ramp). Subsequently, the setpoint of the brake control (CMD) is
set to 0.
After the assumed condition of the brake (Val) has reached value 0 (brake
closed), the state machine changes to "ready to switch on".
Speed shutdown to 0 in state "disable operation active" depending on the
selected ramp (standard ramp) or
action ramp). Subsequently, the setpoint of the brake control (CMD) is set
to 0.
After the assumed condition of the brake (Val) has reached value 0 (brake
closed), the state machine changes to „switched on".
The speed is set to
pn47 fault reaction ref velocity
tive" state. Subsequently, the setpoint of the brake control (CMD) is set to
0.
After the assumed condition of the brake (Val) has reached value 0 (brake
closed), the state machine changes to "fault".
The states "shutdown operation active", "disable operation active" and "fault
reaction active" are only carried out with the appropriate setting of the state
machine.
➢ Make sure that the appropriate settings have been made in object
state machine
properties.
Function
Waiting time of Ref↑ to Sig↑
Waiting time of Sig↑ to Val↑
Waiting time of Ref↓ to Sig↓
Waiting time of Sig↓ to Val↓
Function
Status of the brake control
pn47 fault reaction ref velocity
pn47 fault reaction ref velocity
in the "fault reaction ac-
(fault
(fault re-
co32
35