86 Appendix D: Using the I/O signals and controlled-current output of Matrox Iris GT

Connecting to an NPN-compatible PLC device

To connect your Matrox Iris GT to an NPN-compatible PLC device, connect the
ground of the NPN-compatible PLC device and the ground of your Matrox
Iris GT to a common ground. In addition, an auxiliary output signal of your
Matrox Iris GT must be connected to the device's sinking input.
The NPN-compatible PLC device provides its own power source. When the
Matrox Iris GT output signal is "on", the NPN-compatible PLC device connects
to the ground and completes the circuit.
Matrox Iris GT digital I/O
and power connector
AUX(USER)_OPENC_OUT6
1
Note that the output can sink up to
100 mA.
+24V
NPN input
(active low)
1
GND
Power
source
Input-
sensing
GND
NPN-compatible
PLC
device