Connecting external devices to input signals
The following information relates to the version of Matrox Iris GT that supports
5 V auxiliary input signals. For the information pertaining to the version of
Matrox Iris GT that supports 24 V auxiliary input signals, refer to the Connecting
external devices to input signals section, in Appendix D: Using the I/O signals and
controlled-current output of Matrox Iris GT.
You can connect a wide variety of external devices to the input signals of your
Matrox Iris GT, such as external triggering devices.
Your Matrox Iris GT auxiliary input and trigger signals can have a 5 V, 12 V, or
24 V power source. For information regarding the electric specifications regarding
the ON and OFF voltage levels, see the Matrox Iris GT electrical specifications
section, earlier in this appendix.
An external resistor must be used when dealing with non-TTL signals:
Voltage
5 V
12 V
24 V
Connecting external devices to input signals
External resistor required
0 KΩ and 0 W
1 ΚΩ and ¼ W
3 KΩ and ¼ W
155