154 Appendix J: Using a version of Matrox Iris GT that accepts 5 V auxiliary input signals
Operating voltage and current
I/O specifications
Output signals in IND format
Opto-isolated input signals
Controlled-current output
Matrox Iris GT electrical specifications
The following specifications detail the version of Matrox Iris GT that supports
5 V auxiliary input signals. For the electrical specifications pertaining to the
version of Matrox Iris GT that supports 24 V auxiliary input signals, refer to the
Electrical specifications section, in Appendix B: Technical Reference.
GT300, GT300C, GT1200, GT1200C, GT1900, GT1900C (5 V input version)
12 V provided: 1000 mA used ± 10%.
24 V provided: 500 mA used ± 10%.
Open collector driver.
Operating voltage range: Up to 24 V.
Sink currents: Minimum: 0 mA, Maximum: 100 mA.
Maximum leakage current 10
ON voltage drop 25 mV.
Maximum inrush current 4 A for 300
OFF to ON response 250 nsec.
ON to OFF response 250 nsec.
Operating voltage
Input current
External resistor requirement
ON voltage level
OFF voltage level
Minimum ON current
Maximum OFF current
OFF to ON response
ON to OFF response
Operating voltage
Output voltage
Output current
μ
A max.
μ
s max.
TTL (5 V)
12 V
6.8 mA
6.8 mA
--
1 kΩ
> 2.7 V
> 5.3 V
< 1.8 V
< 2.0 V
2.5 mA
2.5 mA
0.25 mA
0.25 mA
250 nsec
250 nsec
250 nsec
250 nsec
24 V
2.4 V to 21 V
0 to 500 mA max
24 V
6.8 mA
3 kΩ
>10.16 V
< 2.5 V
2.5 mA
0.25 mA
250 nsec
250 nsec
12 V
2.4 V to 10 V
0 to 500 mA max