100 Appendix G: Using a version of Matrox GatorEye that accepts 5 V input signals

Connecting to an external triggering device

To connect your Matrox GatorEye to an external triggering device, connect the
negative opto-isolated trigger input line of your Matrox GatorEye to the external
triggering device's ground.
❖ Note that, in this configuration, your Matrox GatorEye and the trigger generator
are partially isolated because they share a common ground.
3K 0.25W
LineTrig +
LineTrig -
Matrox GatorEye
digital I/O and
power connector
1KΩ 0.25W
LineTrig +
LineTrig -
Matrox
GatorEye
digital I/O and
power connector
LineTrig +
LineTrig -
Matrox
GatorEye
digital I/O and
power connector
Trigger generator
(up to 24 V)
Ω
Out 0
GND
Trigger generator
(up to 12 V)
Out 0
GND
Trigger generator
(TTL)
Out 0
GND