Operating voltage and current
I/O specifications
Output lines
Opto-isolated input lines
Controlled-current output
a. The external resistor requirement for your 5 V input version of Matrox GatorEye is 3
in Appendix G: Using a version of Matrox GatorEye that accepts 5 V input signals.
b. Note that CCS is not available if using power-over-Ethernet (PoE).

Matrox GatorEye specifications

The following specifications detail your Matrox GatorEye.

Electrical specifications

GE300, GE1200, GE1900
12 V provided: 375 mA to 400 mA used.
24 V provided: 200 mA used.
Power-over-Ethernet: 5600 mW power consumption (typical max: 56 V @ 0.1 A)
IEEE 802.3af compliant
Open collector driver.
Operating voltage range: Up to 24 V.
Sink currents: Minimum: 0 mA, Maximum: 100 mA.
Maximum leakage current 10 μA max.
ON voltage drop 25 mV.
Maximum inrush current 4 A for 300 μs max.
OFF to ON response 250 nsec.
ON to OFF response 250 nsec.
Operating voltage
Input current
External resistor requirement
ON voltage level
OFF voltage level
Minimum ON current
Typical OFF voltage
OFF to ON response
ON to OFF response
Operating voltage
b
Output voltage
Output current
Matrox GatorEye specifications
12 V
2.4 V to 10 V
0 to 500 mA max
. For more details, see the Matrox GatorEye electrical specifications section,
65
24 V
1.6 mA
a
0 kΩ
>15 V
< 0.8 V
0.5 mA
2 V
5 μsec
25 μsec
24 V
2.4 V to 21 V
0 to 500 mA max