Feature name
Description
Counter Event Source
Returns or sets the signal or event to be used as the source for the GenICam-specified feature.
Counter Reset Source
Counter Trigger Source
Timer Selector Source
Trigger Source
Unless otherwise specified, the data type of the following feature values is integer.
Matrox GatorEye
GenICam-extension feature value
EncoderAnyDirectionTick
EncoderClockwiseTick
EncoderCounterClockwiseTick
EncoderNewClockwiseTick
LineGreenLED
Linen
LineRedLED
LineTrig
Matrox GatorEye GenICam-extension features
Description
Specifies to use the rotary counter as the event source. The event occurs
when the rotary counter increments (clockwise pulse) or decrements
(counter-clockwise pulse).
Specifies to use the rotary counter as the event source. The event occurs
when the encoder clockwise pulse occurs (that is, when the rotary counter
increments).
Specifies to use the rotary counter as the event source. The event occurs
when the encoder counter-clockwise pulse occurs (that is, when the rotary
counter decrements).
Specifies to use the rotary counter as the event source. The event occurs
when the next new clockwise pulse occurs after the rotary counter has
been decremented. For example, assume your rotary encoder is connected
to a conveyor belt. The conveyor belt stops when the rotary counter is at
42. The stop forces the rotary encoder to reverse by two pulses (back to
40). When the conveyor belt starts up again, the rotary encoder will start
producing clockwise pulses again; however, the rotary counter must reach
the next new value (that is, 40 +2 +1 = 43) before the event occurs.
Specifies to use the signal routed on the internal line that turns the green
element of the User LED on or off, as the signal source. Note that, if both
the green element and the red element are both on, the User LED appears
orange in color.
Use the GenICam-Standard ...Activation feature to specity the change of
state on which to cause the event.
Specifies to use the signal routed on Linen, where n is a value from 0 to 7,
as the signal source. For more information relating to these lines, refer to
the Digital I/O and power connector subsection of the Matrox GatorEye
connectors section, in Appendix B: Technical Reference.
Use the GenICam-Standard ...Activation feature to specity the change of
state on which to cause the event.
Specifies to use the signal routed on the internal line that turns the red
element of the User LED on or off, as the signal source. Note that, if both
the green element and the red element are both on, the User LED appears
orange in color.
Use the GenICam-Standard ...Activation feature to specity the change of
state on which to cause the event.
Specifies to use the signal routed on the Matrox GatorEye dedicated trigger
line.
Use the GenICam-Standard ...Activation feature to specity the change of
state on which to cause the event.