98 Appendix G: Using a version of Matrox GatorEye that accepts 5 V input signals
Operating voltage and current
I/O specifications
Output lines in IND format
Opto-isolated input lines
Controlled-current output
*. Note that CCS is not available if using power-over-Ethernet (PoE).

Matrox GatorEye electrical specifications

The following specifications detail the version of Matrox GatorEye that supports
5 V auxiliary input signals. For the electrical specifications pertaining to the
version of Matrox GatorEye that supports 24 V input signals, refer to the Electrical
specifications section, in Appendix B: Technical Reference.
GE300, GE300C, GE1200, GE1200C, GE1900, GE1900C (5 V input version)
12 V provided: 375 mA used ± 10%.
24 V provided: 200 mA used ± 10%.
Power-over-Ethernet: 5600 mW used (of 56V @ 0.1A)
Open collector driver.
Operating voltage range: Up to 24 V.
Sink currents: Minimum: 0 mA, Maximum: 100 mA.
Maximum leakage current 10
ON voltage drop 25 mV.
Maximum inrush current 4 A for 300
OFF to ON response 250 nsec.
ON to OFF response 250 nsec.
Operating voltage
Input current
External resistor requirement
ON voltage level
OFF voltage level
Minimum ON current
Maximum OFF current
OFF to ON response
ON to OFF response
*
Operating voltage
Output voltage
Output current
μ
A max.
μ
s max.
TTL (5 V)
12 V
6.8 mA
6.8 mA
--
1 kΩ
> 2.7 V
> 5.3 V
< 1.8 V
< 2.0 V
2.5 mA
2.5 mA
μ
μ
250
A
250
250 nsec
250 nsec
250 nsec
250 nsec
24 V
2.4 V to 21 V
0 to 500 mA max
24 V
6.8 mA
3 kΩ
>10.16 V
< 2.5 V
2.5 mA
μ
A
250
A
250 nsec
250 nsec
12 V
2.4 V to 10 V
0 to 500 mA max