70 Appendix B: Technical Reference
Pin number
Line name
15
LineTrig-
16
GND
17
CCS
8,9
PWR
A cable for this connector can be purchased from Matrox (GT-CBL-PWR/3*).
To build your own digital I/O and power cable, parts can be purchased from:
Manufacture
Part number:
Description:
Description
Opto-isolated trigger input line, negative.
Note that, when connected to the Matrox Breakout Box, this pin must be
connected to ground.
Ground. This ground is reserved for use with the ground from your power
supply.
Controlled-current output, designed to be connected to an illuminator
(0-500 mA, intensity controlled using an internal pulse-train strobe line,
generated with a pulse width modulator (PMW) and exposure timer 2).
Note that when you use a 24 V power source for your Matrox GatorEye, the CCS
can output from 2.4 V to 21 V to your illuminator. If, however, you use a 12 V
power source, the CCS can output from 2.4 V to 10 V to your illuminator.
If using PoE, this pin can not used.
Power provided to your Matrox GatorEye. The power must be either +12 V or
+24 V +/- 10%. The amount of power required is determined by the power
requirements of the devices attached to your Matrox GatorEye (such as a ring
LED).
Note that, if using PoE, this pin should not be connected.
Cable information
Phoenix Contact GmbH & Co. KG
SAC-17P- 3,0-PVC/FS SCO Order No.: 1555350
Sensor/actuator cable, 17-pos., black PVC, straight M12 SPEEDCON
socket on the free conductor end, length: 3.0 m