Pin number
Line name
1
RxD_RS232
2
Line7
3
Line5
4
Reserved
5
Line2+
6
Line1+
7
LineTrig+
10
TxD_RS232
11
Line6
12
Line4
13
Line3+
14
Line0+
The pinout for the digital I/O and power connector is as follows:
Description
RS-232 receive.
Open-collector auxiliary line 7 (output).
Supported signals: acquisition active, frame active, frame trigger wait, auxiliary
input or dedicated trigger redirect, timer active (can be used as a standard
strobe), counter active, exposure active, user-defined (output).
Open-collector auxiliary line 5 (output).
Supported signals: acquisition active, frame active, frame trigger wait, auxiliary
input or dedicated trigger redirect, timer active (can be used as a standard
strobe), counter active, exposure active, user-defined (output).
Do not connect.
Opto-isolated auxiliary line 2 (input), positive.
Supported signals: User-defined (input), counter event source, trigger, or
quadrature input bit A or B.
Note: The negative component of this line is internally connected to the ground.
Opto-isolated auxiliary line 1 (input), positive.
Supported signals: User-defined (input), counter event source, trigger, or
quadrature input bit A or B.
Note: The negative component of this line is internally connected to the ground.
Opto-isolated trigger input line, positive.
RS-232 transmit.
Open-collector auxiliary line 6 (output).
Supported signals: acquisition active, frame active, frame trigger wait, auxiliary
input or dedicated trigger redirect, timer active (can be used as a standard
strobe), counter active, exposure active, user-defined (output).
Open-collector auxiliary line 4 (output).
Supported signals: acquisition active, frame active, frame trigger wait, auxiliary
input or dedicated trigger redirect, timer active (can be used as a standard
strobe), counter active, exposure active, user-defined (output).
Opto-isolated auxiliary line 3 (input), positive.
Supported signals: User-defined (input), trigger, counter event source, or
quadrature input bit A or B.
Note: The negative component of this line is internally connected to the ground.
Opto-isolated auxiliary line 0 (input), positive.
Supported signals: User-defined (input), trigger, counter event source, or
quadrature input bit A or B.
Note: The negative component of this line is internally connected to the ground.