When installing the STP pump horizontally using a crane or other appropriate, support pump casing,
or pump base (see Figure 13). DO NOT apply face on convex parts, such as the outlet port or
2
connectors by ropes. Doing so may the pump to fall, or deform and damage the parts.
A crane due to lifting operations should withstand the load of five times or more the weight of the
STP pump, and rope should be seven time or more. When lifting the pump, use 2 or more ropes.
When jacking up the bottom of the STP pump, a device due to jacking up the STP pump should
withstand the load of five times or more the weight of the STP pump.
MT-00E-2A1-C
Page 18
STP Series Turbomolecular Pump
Figure 13 - Example of lifting the STP pump (horizontal positioning)
Figure 14 - Jack-up the STP pump