c) Point the water or the air straight at the hydraulic
oil cooler, parallel with the cooling fins.
To clean the hydraulic oil cooler (DXR 275,
DXR 305, DXR 315)
WARNING:
hydraulic oil cooler become cool before you
clean it.
Clean the area around the hydraulic oil cooler with
water and weak cleaning agent.
Clean the cooling fins on the hydraulic oil cooler with
compressed air.
If the cooling fins do not become clean with
compressed air, use a high pressure washer and a
cleaning agent.
To prevent damage to the cooling fins, obey these
instructions:
a) Only use maximum pressure of 100 bar/1450 psi.
b) Make sure that there is a minimum of 40 cm/
15.7 in. between the hydraulic oil cooler and the
nozzle.
90
Risk of burn injury. Let the
c) Point the water or the air straight at the hydraulic
oil cooler, parallel with the cooling fins.
To clean the electrical components
Clean the electric motor, the electrical enclosure,
the electrical terminals and the other electrical
components. Use a cloth or compressed air.
CAUTION:
directly on the electrical components.
Clean the outer parts of the remote control with
a moist cloth. Clean the inner parts of the remote
control with compressed air.
CAUTION:
pressure washer on the remote control.
To clean the batteries and the battery charger
CAUTION:
the battery charger with water.
Make sure that the batteries and the battery charger
are clean and dry before you connect the batteries to
the battery charger.