Husqvarna DXR 95 Operator's Manual page 67

Table of Contents

Advertisement

Available languages

Available languages

"Pressure" will only calibrate the hydraulic pressure
control function and does not adjust customer
specified valve adjustment. Refer to
hydraulics with "Auto (calibrate)" on page 67 .
With the function "Manual (calibrate)" you can
calibrate components on the product one by one.
With the function "Boom pressure" you can adjust
the maximum hydraulic pressure for the arm system.
The hydraulic pressure changes with 5 bar/72.5
psi intervals. Adjust the hydraulic pressure between
180bar/2610 psi to 150 bar/2175.6 psi (DXR 95) or
200 bar/2901 psi to 150 bar/2175.6 psi (DXR 145,
DXR 275, DXR 305, DXR 315).
"Reset to factory settings" resets the hydraulic
system.
To calibrate the hydraulics with "Auto (calibrate)"
During calibration of the valves, the product can make
small movements.
1. Disconnect the hydraulic hoses from the installed
tool.
Note:
It is not necessary to remove the tool from
the product.
2. Start the product. Refer to
95) on page 70 and To start the product (DXR 145)
on page 71 and To start the product (DXR 275,
DXR 305, DXR 315) on page 72 .
3. Extend the outriggers. Refer to
outriggers on page 83 .
4. Press the menu button (A) on the remote control.
12345 H
A
5. Select "Calibrate hydraulics" in the "Controls" menu
on the display.
6. Select "Auto (calibrate)".
7. Select "Pressure and valves" or "Pressure".
1401 - 005 - 11.01.2024
To calibrate the
To start the product (DXR
To operate the
XX BAR
8. Push the left top button (B) on the right joystick (C).
9. Push the right joystick forward until the calibration is
completed.
"Control diagnostics"
In "Control diagnostics" you can do function tests of the
controls on the remote control. Each control is shown in
the display. The control indicators in the display changes
from white to orange when you do the function tests.
Operate a control on the remote control to its maximum.
The control operates correctly when the control indicator
shows 100% in the display.
CONTROL DIAGNOSTICS
O% O%
O% O%
O% O%
O% O%
PRESS AND HOLD BACK TO EXIT
"System" menu
Tools
Machine status
Functions
Controls
System
0%
PRESSURE CALIBRATION
50 bar / 725 PSI
ACTIVATE AND PUSH RIGHT JOYSTICK
FORWARD
B
C
1
2
3
1
2
1
2
Remote settings
Revisions
Third party licenses
Factory settings
67