Husqvarna DXR 95 Operator's Manual page 106

Table of Contents

Advertisement

Available languages

Available languages

To do a check of the oil level in the
drive motor (DXR 145, DXR 275, DXR
305, DXR 315)
1. Start the product. Refer to
145) on page 71 and To start the product (DXR 275,
DXR 305, DXR 315) on page 72 .
2. Operate the caterpillar tracks until 1 of the plugs is
level with the center of the hub. The other plug is in
the top position.
3. Park the product on level ground and stop the
To stop the product (DXR 145) on
product. Refer to
page 83 and To stop the product (DXR 275, DXR
305, DXR 315) on page 84 .
4. Clean the area around the plugs to prevent
contamination of the drive motor system.
5. Remove the level plug (A).
6. Look in the level plug hole (B). The oil level is correct
when the oil is at the edge of the level plug hole.
106
To start the product (DXR
B
A
7. If the oil level is low, open the top plug (C) and fill the
oil through the top plug hole. Fill the oil slowly until
oil comes out from the level hole. Refer to
data on page 143 .
8. Install the level plug and the top plug.
To do a check of the quantity of grease
in the breaker grease pump (DXR 95)
1. Park the product on level ground and stop the
To stop the product (DXR 95) on
product. Refer to
page 83 .
2. Examine the quantity of grease in the grease pump.
MAX
MIN
.
Technical
C
1401 - 005 - 11.01.2024