Husqvarna DXR 95 Operator's Manual page 150

Table of Contents

Advertisement

Available languages

Available languages

SB 52
Recommended
4.0/58.
water pressure,
bar/PSI
Water consump-
≤5.0 /
tion at 4 bar/58
≤1.3
PSI, l/min /gpm
Water
pres-
3.0/43.
sure,
bar/PSI
Mini-
mum
Water
require-
con-
ments
sump-
5.0/1.3
tion,
l/min /g
pm
Guide values for connection to a mains
socket
The mains socket must have the same amperage as the
extension cable and the electrical socket on the product.
DXR 95: Motor 9.8 kW
Nominal from
Cable area,
power source,
AWG/mm
V
12/4
400
14/2.5
12/4
460
14/2.5
DXR 145: Motor 18.5 kW
150
Breaker
SB 102
SB 152
4.0/58.
0
0
≤5.0 /
≤5.0 / ≤1.3
≤1.3
3.0/43.
5
5
5.0/1.3
Start current,
2
A
52
48
Tool
SB 202
SB 302 DCR 90
2.0/29.
4.0/58.0
0
<9.0 /
6.5/1.7
≤2.4
1.0/14.
3.0/43.5
5
5.0/1.3
3.0/0.8
The incoming voltage must be in the range +/- 10% of
the nominal voltage.
Depending on the fuse and the mains power supply,
you might need a shorter cable. Speak to the person
responsible for the work site.
Motor output,
Frequency, Hz
50
60
Concrete crusher
DCR
DCR
100
300
2.0/29.0
6.5/1.7
1.0/14.5
3.0/0.8
Setting ther-
mal overload
kW
relay, A
18
9.8
16
1401 - 005 - 11.01.2024
Drum cutter
ER 40
ER 50
2.0/29.
2.0/29.
0
0
7.9/2.1
7.9/2.1
1.5/21.
1.5/21.
8
8
4.1/1.1
4.1/1.1
Max. cable
length, m/ft
125/410
80/260
165/540
105/430

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dxr 145Dxr 275Dxr 305Dxr 315