Section 5 – Procedures

5.7 Display Module

5.7-1 Calibration and Diagnostic Tool Key
Functions
WARNING
Only trained and authorized personnel shall be
permitted to service an MEWP .
WARNING
Read all instructions closely before attempting each
phase of the calibration procedure.
The display module can be used to calibrate and
diagnose MEWP issues.
The display module can be found in the base control
cnosole. The display shows the battery charge, hour
meter and traction speed.
Display Controls
Symbol
241914ACA
112
Key Function
ENTER Button
Choose the current selection
or save the changes
LEFT Button
Go back to the previous
menu or move the cursor to
the left.
RIGHT Button
Move the cursor to the right
UP/DOWN Buttons
Scroll through the display
menu or change the value.
Initial State
If Alarm
Occurs
Press the middle button twice to
enter the display option
Press the up or down buttons to
scroll through the display menu.
Main Menu
LANGUAGE
MACHINE TYPE
REGION
BATTERY TYPE
CONSOLE
PASSWORD
CALIBRATION
Display Module
ALARMS
PAGE
Shows alarm code
and node number.
Select this menu to
change the language of
the display.
Select this menu to
change the type of
machine where the display
is installed.
Select this menu to
change the region where
the machine is being
used.
Select this menu to change
what type of battery is
installed on the machine.
Select this menu to
change which console
you are connected to.
Select this menu and
select the correct code to
enable adjustments and
calibrations.
This menu is to be used
by Skyjack engineers
only!