Display Module
Name
Unit of Measure
A2 EV4
JOYD 1:DRIVE M
JOYD 2:LIFT M
JOYD 3:HORN
JOYD 4:DECK LIM
JOYD 5:SERVICE
JOYD 6:FOOT KC
JOYD
7:PLATFORM
JOYD 8:KC SWNO
JOYD 9:KC SWNC
JOYD10:INDOOR
JOYD13:ENABLE
JOYD14:STEER L
JOYD15:STEER R
JOYSTICK: FAULT
JOYA 1: Y AXIS
JOYO 1: LED 1
JOYO 2: LED 2
JOYO 3: LED 3
LOAD C. WEIGHT
1
LOAD C. WEIGHT
2
LOAD C. WEIGHT
3
LOAD C. ERROR
LOAD C. MOTION
LOAD C. W.10KG
LOAD C. OVER W.
LOAD C.UNDER
W.
LOAD C.R
WEIGHT1
LOAD C.R
WEIGHT2
SJ12 E, SJ16 E, SJ20 E
Description
OFF/ON
PWM modulation applied to the EV4 output A2. (All Motion Sounder)
OFF/ON
Status of the Digital Input at the Platform Joystick for Drive Mode
OFF/ON
Status of the Digital Input at the Platform Joystick for Lift Mode
OFF/ON
Status of the Digital Input at the Platform Joystick for Horn
OFF/ON
Status of the Digital Input at the Platform Joystick for Deck Limit Switch
OFF/ON
Status of the Digital Input at the Platform Joystick for Service Limit Switch
OFF/ON
Status of the Digital Input at the Platform Joystick for the Limit Switch
OFF/ON
Status of the Digital Input at the Platform Joystick for the Platform Active Switch
OFF/ON
Status of the Digital Input at the Platform Joystick for the KC N/O
OFF/ON
Status of the Digital Input at the Platform Joystick for the KC N/C
OFF/ON
Status of the Digital Input at the Platform Joystick for the Indoor Mode Active
OFF/ON
Status of the Digital Input at the Platform Joystick for the Joystick Enable Switch
Status of the Digital Input at the Platform Joystick for the Joystick Steer Left
OFF/ON
Switch
Status of the Digital Input at the Platform Joystick for the Joystick Steer Right
OFF/ON
Switch
OFF/ON
Joystick in fault state
ANALOGUE
(BYTE2)*256+(BYTE3) gives 0-65535 value representing 0V-5V
OFF/ON
Status of the LED Output for Power ON
OFF/ON
Status of the LED Output for Drive Mode
OFF/ON
Status of the LED Output for Lift Mode
WEIGHT
Weight measured at the Load Cell 1
(Kg)
WEIGHT
Weight measured at the Load Cell 2
(Kg)
WEIGHT
Weight measured at the Load Cell 3
(Kg)
OFF/ON
see load cell protocol
OFF/ON
see load cell protocol
OFF/ON
see load cell protocol
OFF/ON
see load cell protocol
OFF/ON
see load cell protocol
WEIGHT
Weight measured at the Redundant Load Cell 1 (not always present)
(Kg)
WEIGHT
Weight measured at the Redundant Load Cell 2 (not always present)
(Kg)