Section 5 – Procedures
Name
Unit of Measure
JOYD 3:HORN
JOYD 4:DECK LIM
JOYD 5:SERVICE
JOYD 6:FOOT KC
JOYD
7:PLATFORM
JOYD 8:KC SWNO
JOYD 9:KC SWNC
JOYD10:INDOOR
JOYD13:ENABLE
JOYD14:STEER L
JOYD15:STEER R
JOYSTICK: FAULT
JOYA 1: Y AXIS
JOYO 1: LED 1
JOYO 2: LED 2
JOYO 3: LED 3
LOAD C. WEIGHT
1
LOAD C. WEIGHT
2
LOAD C. WEIGHT
3
LOAD C. ERROR
LOAD C. MOTION
LOAD C. W.10KG
LOAD C. OVER W.
LOAD C.UNDER
W.
LOAD C.R
WEIGHT1
LOAD C.R
WEIGHT2
LOAD C.R
WEIGHT3
LOAD C.R ERROR
241914ACA
150
Description
OFF/ON
Status of the Digital Input at the Platform Joystick for Horn
OFF/ON
Status of the Digital Input at the Platform Joystick for Deck Limit Switch
OFF/ON
Status of the Digital Input at the Platform Joystick for Service Limit Switch
OFF/ON
Status of the Digital Input at the Platform Joystick for the Limit Switch
OFF/ON
Status of the Digital Input at the Platform Joystick for the Platform Active Switch
OFF/ON
Status of the Digital Input at the Platform Joystick for the KC N/O
OFF/ON
Status of the Digital Input at the Platform Joystick for the KC N/C
OFF/ON
Status of the Digital Input at the Platform Joystick for the Indoor Mode Active
OFF/ON
Status of the Digital Input at the Platform Joystick for the Joystick Enable Switch
Status of the Digital Input at the Platform Joystick for the Joystick Steer Left
OFF/ON
Switch
Status of the Digital Input at the Platform Joystick for the Joystick Steer Right
OFF/ON
Switch
OFF/ON
Joystick in fault state
ANALOGUE
(BYTE2)*256+(BYTE3) gives 0-65535 value representing 0V-5V
OFF/ON
Status of the LED Output for Power ON
OFF/ON
Status of the LED Output for Drive Mode
OFF/ON
Status of the LED Output for Lift Mode
WEIGHT
Weight measured at the Load Cell 1
(Kg)
WEIGHT
Weight measured at the Load Cell 2
(Kg)
WEIGHT
Weight measured at the Load Cell 3
(Kg)
OFF/ON
see load cell protocol
OFF/ON
see load cell protocol
OFF/ON
see load cell protocol
OFF/ON
see load cell protocol
OFF/ON
see load cell protocol
WEIGHT
Weight measured at the Redundant Load Cell 1 (not always present)
(Kg)
WEIGHT
Weight measured at the Redundant Load Cell 2 (not always present)
(Kg)
WEIGHT
Weight measured at the Redundant Load Cell 3 (not always present)
(Kg)
OFF/ON
see load cell protocol