Skyjack SJ12 E Service Manual page 151

Vertical mast lifts
Hide thumbs Also See for SJ12 E:
Table of Contents

Advertisement

Display Module
Name
Unit of Measure
LOAD C.R
MOTION
LOAD C.R W.10KG
LOAD C.R OVER
W.
LOAD C.R UNDER
W
CTRAP HW
CPU TIME F US
CPU TIME US
TILT PITCH
TILT ROLL
TILT STATUS
TILT
TEMPERATURE
OUTDOOR MODE
OVER HEIGHT
PULSE DOWN
STATE
SJ12 E, SJ16 E, SJ20 E
Description
OFF/ON
see load cell protocol
OFF/ON
see load cell protocol
OFF/ON
see load cell protocol
OFF/ON
see load cell protocol
Number
Slave motor: number of occurrences of hardware-detected overcurrent events.
(1)
Reserved Zapi internal use
Reserved Zapi internal use
Degrees
reading of the internal tilt sensor in degrees for the Pitch Angle
(0.01°)
Degrees
reading of the internal tilt sensor in degrees for the Roll Angle
(0.01°)
OFF/ON
Tilt sensor status.
Celsius
Temperature of the internal Tilt Sensor
(0.1 °C)
status of the outdoor mode function:
OFF/ON
OFF = indoor;
ON = outdoor
status of the over height function:
Number
0 = under height;
(1)
1 = over height;
2 = over height with over shot;
Number
status of the pulse down function
(1)
Section 5 – Procedures
241914ACA
151