I/O ALARM SETTINGS

Read the description under the following figures for this menu page: At this point, the alarms can be set according to the
different states.
Here is a brief description:
Alarm In: This is used to select the required alarm number.
Alarm Type: This is used to select three options, i.e. NO (Normal Open), NC (Normal Close) and OFF. By selecting
"Normal Open", the I/O state alarm will be activated when the sensor is ON; by setting Normal Close", the I/O state
alarm will be activated when the sensor is OFF; by setting "OFF", the I/O state will not trip.
Buzzer: This can be used to program the time of the auditory signal generated when a sensor alarm is detected (OFF,
10sec, 20sec, 40sec, 60sec).
Alarm Out: This can be used to match the correct external alarm sensor number.
Latch Time: This can be used to set the external sensor alarm time when a sensor alarm is detected (10sec, 20sec,
40sec, 60sec).
Channel: This can be used to match the channel with the I/O alarm. The channel will be activated in case of alarm
detection.
Post Recording: This can be used to set the recording time at the end of the alarm (10sec, 30sec, 1min, 2min, 5min).
Show Message: This can be used to set the appearance of the icon on the screen when a sensor alarm is detected.
For icon types, see section "0 - Live interface and pop-up menu"
Send Email: This can be used to send alarm images to a specific email address (for more information, see "3.9.3 -
Email").
Full screen: This can be used to set displaying the video in full-screen mode when an alarm event is detected.
FTP Picture Upload: This can be used to send the image to the FTP server in case of I/O alarm event.
FTP Video to Upload: This can be used to send the video to the FTP server in case of I/O alarm event.
Picture to Cloud: This can be used to send the video to Cloud Server in case of an I/O alarm.
Video to Cloud: This can be used to send the video to Cloud Server in case of an I/O alarm.
Copy: This can be used to copy the I/O parameters to any other I/O.
Default: This can be used to restore the default alert settings.
Apply to save the changes.
Alarm type
The alarm trips when an object moves in the motion detection area. The sensitivity level can
Motion/PIR
be adjusted according to application needs.
The alarm can convert the alarm signal emitted by the external sensor into a signal that can
IO Alarm
be identified by the system itself.
DS1097-024C