I/O ALARM SETTINGS
Read the description under the following figures for this menu page: At this point, the alarms can be set according to the
different states.
Here is a brief description:
•
Alarm In: This is used to select the required alarm number.
•
Alarm Type: This is used to select three options, i.e. NO (Normal Open), NC (Normal Close) and OFF. By selecting
"Normal Open", the I/O state alarm will be activated when the sensor is ON; by setting Normal Close", the I/O state
alarm will be activated when the sensor is OFF; by setting "OFF", the I/O state will not trip.
•
Buzzer: This can be used to program the time of the auditory signal generated when a sensor alarm is detected (OFF,
10sec, 20sec, 40sec, 60sec).
•
Alarm Out: This can be used to match the correct external alarm sensor number.
•
Latch Time: This can be used to set the external sensor alarm time when a sensor alarm is detected (10sec, 20sec,
40sec, 60sec).
•
Channel: This can be used to match the channel with the I/O alarm. The channel will be activated in case of alarm
detection.
•
Post Recording: This can be used to set the recording time at the end of the alarm (10sec, 30sec, 1min, 2min, 5min).
•
Show Message: This can be used to set the appearance of the icon on the screen when a sensor alarm is detected.
For icon types, see section "0 - Live interface and pop-up menu"
•
Send Email: This can be used to send alarm images to a specific email address (for more information, see "3.9.3 -
Email").
•
Full screen: This can be used to set displaying the video in full-screen mode when an alarm event is detected.
•
FTP Picture Upload: This can be used to send the image to the FTP server in case of I/O alarm event.
•
FTP Video to Upload: This can be used to send the video to the FTP server in case of I/O alarm event.
•
Picture to Cloud: This can be used to send the video to Cloud Server in case of an I/O alarm.
•
Video to Cloud: This can be used to send the video to Cloud Server in case of an I/O alarm.
•
Copy: This can be used to copy the I/O parameters to any other I/O.
•
Default: This can be used to restore the default alert settings.
•
Apply to save the changes.
Alarm type
The alarm trips when an object moves in the motion detection area. The sensitivity level can
Motion/PIR
be adjusted according to application needs.
The alarm can convert the alarm signal emitted by the external sensor into a signal that can
IO Alarm
be identified by the system itself.
DS1097-024C
Function
53