Unpacking The System; Scope Of Delivery - ABB ProKiln GAC400 Operating Instruction

Probe gas sampling system
Table of Contents

Advertisement

38
ProKiln GAC400 PROBE GAS SAMPLING SYSTEM | OI/GAC400-EN REV. A
... 5 Transport and storage
... Transport
Environmental conditions
Observe the following physical limits when transporting the
modules:
Module
Environmental conditions for transport
Ambient temperature: +5 °C to +45 °C, after completely
Retractor unit
including the
draining all water and drying parts in contact with cooling
probe
water or condensation: -20 °C to +45 °C
Air humidity: Year-round average max. 75 %, short-term max.
95 %, occasional slight condensation is permitted
Cooling unit
Ambient temperature: +5 °C to +55 °C, after completely
draining all water and drying parts in contact with cooling
water or condensation: -20 °C to +55 °C
Air humidity: Year-round average max. 75 %, short-term max.
95 %, occasional slight condensation is permitted
Water unit
Ambient temperature: +5 °C to +45 °C, after completely
draining all water and drying parts in contact with cooling
water or condensation: -20 °C to +45 °C
Air humidity: Year-round average max. 75 %, short-term max.
95 %, occasional slight condensation is permitted
Control cabinet Ambient temperature: -20 °C to +45 °C
Air humidity: Year-round average max. 75 %, short-term max.
95 %, occasional slight condensation is permitted
Flange shutter Ambient temperature: -20 °C to +55 °C
Air humidity: Year-round average max. 75 %, short-term max.
95 %, occasional slight condensation is permitted

Unpacking the system

Instructions
Perform the following steps to unpack the system:
1. Remove outer packaging:
Transport crate
Tensioning straps
Cardboard, films, and wooden parts
2. Undo fasteners holding the system parts on the pallet.
Before doing it, take care that the equipment stands in a
stable way and cannot fall down.
3. Lift system parts off the pallet with a crane, fork-lift truck or
hand lift (recommended at least 2 persons for hand-lifting).
Note: The retractor must not be transported with a fork-lift
truck.
4. Dispose of packaging material in accordance with the
national regulations.
5. Transport system parts to the place of installation

Scope of delivery

Scope of delivery (standard)
The following components are delivered as standard:
Probe retractor including probe
Control cabinet
Water panel
Cooling panel with 1" hoses for connection to water panel
Complete electrical documentation in electronic format
System operating instructions in electronic format
Also supplies (filter tools, set of O-rings, leakages test plug)
Electrical documentation and operating instructions in print-
out version placed in door of control cabinet
Scope of delivery (optional)
The following optional components may be included in the scope
of delivery:
Automatic flange shutter
Water tank heater for ambient temperature below +5C°
Double probe configuration
Heated sample shut-off valve (attached to retractor frame)
Air tank 270 L CE approved