Dismounting And Disposal; Safety Instructions - ABB ProKiln GAC400 Operating Instruction

Probe gas sampling system
Table of Contents

Advertisement

126
ProKiln GAC400 PROBE GAS SAMPLING SYSTEM | OI/GAC400-EN REV. A

13 Dismounting and disposal

Safety instructions

Take into consideration the following safety instructions for all
actions related to dismounting and disposal:
WARNING
Mechanical, thermal and material dangers
Risk of injury in the area of the probe gas sampling system
due to moving or falling parts, anti-freeze, lubricating oil.
Wear general personal protective equipment:
Closed overalls with long trousers and long sleeves
Safety shoes (preferably boots covering ankles)
Safety gloves suitable for mechanical work Safety glasses
Protective helmet
If necessary, additional protective equipment if prescribed
by the operator.
WARNING
Heavy transport units
Danger of crushing when lifting or lowering the transport unit
Only appropriately trained personnel may transport the
transport units and only with the aid of the recommended
transport equipment.
Do not stand under suspended loads.
Follow the transport instructions in these operating
instructions carefully.
WARNING
Hot surfaces, hot gases, jet flames
Risk of burning due to jet flames and hot gases at the
uncovered duct opening when the rotary kiln is in operation.
Preferably install or remove the probe when the rotary kiln
is out of operation.
If you install or remove the probe when the rotary kiln is in
operation:
Wear a face mask against heat, heat-proof gloves and
protective welder's clothing and respiratory protection
against toxic gases.
Keep the time in which the duct opening is open as
short as possible.
CAUTION
Harmful dusts
Danger due to harmful dusts when cleaning the probe gas
sampling system
Wear a dust mask when cleaning.
Wash any dust off the skin immediately with water and
soap
CAUTION
Harmful anti-freeze
Danger of injury to skin and eyes in the event of contact with
cooling water or anti-freeze.
Avoid contact with the cooling water and the anti-freeze.
In case of accidental contact of cooling water or anti-
freeze with skin, wash off the skin immediately with water
and soap. Contact medical specialist according to local
regulations.
If cooling water or anti-freeze gets in the eyes despite
protective glasses, rinse them thoroughly under running
water, holding the eyelids open. Contact medical specialist
according to local regulations.
Observe instructions in the anti-freeze manufacturer's
safety data sheet.
CAUTION
Slippery floor
Risk of falling on slippery floor due to escaped or spilled
cooling water and lubricating oil or dirt.
Always keep the floor around the probe gas sampling
system clean and dry.

Advertisement