20
ProKiln GAC400 PROBE GAS SAMPLING SYSTEM | OI/GAC400-EN REV. A
... 3 Design and function
... Components
Controls on the probe retractor
There are additional controls on the retractor:
Figure 6: Controls on the probe retractor
Pos.
Designation
1
Warning tower
2
Emergency stop
3
Manual push buttons in and out
4
Safety breaker
Flange Shutter
To protect people and equipment from process over-pressure exposure and to limit false ambient air to enter the process, the flange
opening is closed by a shutter when the probe is retracted to its service position.
The flange shutter does not close during regular retraction / extension for cleaning the outside of the probe. The shutter is moved
either by an automatic pneumatic drive flange shutter (optional) or by manual actuation.
Supply lines
The pneumatic/electric supply is connected at a central transition point. All required internal line connections are included and pre-
installed in the probe retractor. Connection cables between units are not supplied with the system.
1
3
Function
Audible warning prior and during movement of probe
Flashlight warning prior and during movement of probe (White)
Indication of system alarm (Red)
Indication of system maintenance request (Yellow)
Indication of system in operation (Green)
Halts all probe movements
Halts all probe cleaning by air
Manual operation of probe movement only active if the probe is in manual operation
Safety breaker for probe motor
When off, the main power to the motor is off and the probe is not able to move
2
4