ProKiln GAC400 PROBE GAS SAMPLING SYSTEM | OI/GAC400-EN REV. A
... 6 Installation

Installing the probe retractor/flange shutter

Screws required for assembly
4 + 4 + 4 suspension bolts, diameter 16 mm, material round steel
S235JR (St37)
Requirements
The following requirements must be met in order to install the
probe retractor/flange shutter:
The site conforms to the designated site conditions (criteria
see Choosing the place of installation of the peripheral
modules).
4 fastening points are present to affix the probe retractor.
The probe retractor and flange shutter is unpacked.
Instructions
How to install the probe retractor:
1. Set up probe retractor at the place of installation.
1 Transport lugs 4×
Figure 35: Transport lugs
2. Suspend probe retractor on transport
lugs (Figure 35, Pos.
1
attachment points are in the front on the flange shutter and
in the back on the retractor mounting flanges.
Note: Pay particular attention to suitable fastening points of
the lifting equipment. Observe relevant local regulations.
3. Lift probe retractor together with flange shutter and
position in front of insertion tube/flange of the kiln wall.
Remove the two mounted transport legs.
Note: Store the transport legs for any future transport.
1
) using suitable lifting gear. The
4. Position probe retractor at the designated position and
install appropriate support. It is important to get a precise
alignment of the retractor angle, both horizontal and vertical,
with respect to the insertion tube/flange of the kiln wall.
1
1 Installation flanges
Figure 36: Installation flanges on probe retractor
5. Connect the appropriate support of the probe retractor and
the system. Maximum load per suspension point is 10000 N;
ensure even loading of the fastening elements.
The fastener elements must connect to the square
installation flanges (Figure 36, Pos.
fastener elements can be placed standing on the floor or
hanging from the ceiling, whatever is preferable.
CAUTION! The screw-in transport lugs are for transporting
the probe retractor only, but not for permanent suspension.
For permanent suspension only use the designated fastening
positions.
6. Remove lifting gear and support material.
7. Check whether probe retractor is fastened stably enough and
adjusted to local conditions.