Error code
Description
244.20
Took too long to ramp up dc feed motor in tray 4. Go to
244.21
Pick motor stall in tray 4.
244.22
Tray 4 pick motor underspeed.
244.24
DC Feed ACM stalled on the last pick attempt in
tray 4.
244.32
Tray not ready.
244.33
Pick received but detected a tray pulled.
244.41
Motor 1 (Pick/Lift) Elevator motor stalled.
244.42
Motor 1 (Pick/Lift) Elevator motor PWM overflow
error (underspeed). Motor underspeed (max PWM
and motor underspeed, typical accordion jam).
244.43
Motor 1 (Pick/Lift) motor ramp (end ramp - did not
reach speed, typical pack feed paper jam).
244.44
Motor 2 (Separator/Pass through) motor stalled.
244.45
Motor 2 (Separator/Pass through) motor PWM
overflow error (underspeed). Motor underspeed
(max PWM and motor underspeed, typical
accordion jam).
244.46
Motor 2 (Separator/Pass through) motor ramp
(end ramp - did not reach speed, typical pack feed
paper jam).
244.47
Motor 3 motor stalled.
244.48
Motor 3 motor PWM overflow error (underspeed).
Motor underspeed (max PWM and motor
underspeed, typical accordion jam).
244.49
Motor 3 motor ramp (end ramp - did not reach
speed, typical pack feed paper jam).
Action
page
Diagnostic information
91
"Option tray jam service check" on
92.
7016